Self-tapping insertsEnquire

SELF-TAPPING INSERT · 302 / 302H

302/302H Self-Tapping Inserts

Form the connection as you install.

External cutting features engage a prepared pilot hole. Matching the hole to the parent material is essential for successful self-tapping installation.

Self-tapping structureCutting slotsPilot-hole preparation
Product rendering · Refer to the approved drawing for actual geometry

DESIGNED FOR CONNECTION

A cutting structure that forms the connection as it turns.

Type 302 self-tapping inserts use cutting slots to form a mating external thread in a suitable parent material as they are installed, while providing an internal screw thread. Pre-tapping requirements and pilot-hole dimensions depend on the material and approved process. Self-tapping does not mean that any hole size is suitable.

01

Create a threaded interface

Provide a metal internal thread in a suitable parent material.

02

Match the pilot hole

Set hole diameter and depth according to material condition.

03

Compare alternatives

Evaluate headed and headless designs according to available space.

01 / STRUCTURE

Start with the right structure.

The insert structure determines how the 302/302H series connects and installs.

Self-tapping insert illustration
Self-tapping insert illustrationIllustration · confirmed drawings define the structure and process
01

Type 302

Slotted cutting structure; select with regard to the parent material and pilot hole.

02

Type 302H

Confirm the meaning of the H suffix and the dimensions against the drawing.

Related product:Explore the related product →

SPECIFICATION & MATCHING

Four essentials for specifying the insert.

Bring connection dimensions and use conditions together for selection and quotation. An existing drawing or complete designation is enough to start.

Internal and external threads
The internal thread matches the screw. Outside diameter, external thread and body length determine the required space in the parent component.
Cutting geometry
Cutting slots, cutting holes and chip reservoirs differ. Identify the specified geometry; a blind-hole designation alone does not mean a closed insert end.
Pilot hole and usable depth
Match the pilot hole to material, hardness and insert geometry. Blind holes also need allowance for the screw end, machining and chips.
Material and delivery condition
Specify insert material, finish, parent material and environment. Available combinations and accompanying documents are confirmed with the quotation.

Have a drawing or sample designation?

Share internal and external dimensions, parent material and quantity. The wire-insert code catalogue does not cover this family.

Discuss this family →

02 / MATERIAL

Match the material to the conditions.

These material options are discussion points; not every model is available in every combination.

01

Stainless steel

Confirm grade, strength and corrosion resistance against the supply drawing.

02

Other materials

Discuss the parent material, environment and connection loads.

03

Material documentation

Specify the material standard and required inspection documents in the order.

03 / SURFACE

The finish is part of the connection.

Finishes serve friction-control, corrosion-resistance or identification purposes, with different operating limits. Quotations list available material and finish combinations.

01

Surface condition

Confirm whether lubrication, protection or another treatment is needed.

02

Mating compatibility

Check the combination of parent material, screw, media and surface treatments.

03

Made to drawing

Include treatment type and thickness in dimensional and acceptance requirements.

TOOLING & COMPATIBILITY

Inserts and tools, as one matched system.

Match the front end to the insert drive, thread and length, and the driver to the front-end interface. Component access determines whether the tool can reach the hole.

01

Product structure

Cutting features form the mating thread in a suitable parent material; pilot-hole size depends on material and insert geometry.

Explore →
02

Compatible tooling

Front-end geometry, thread, length capability and access define the configuration.

Explore →
03

Project requirements

Drawing, substrate, hole type and acceptance scope inform selection.

Explore →

INSPECTION

Identify the inspection object.

Incoming inspection concerns the insert; pre-installation inspection concerns the receiving hole. After installation, inspect the thread, position and function. Product drawings and acceptance specifications define gauges, criteria and records.

Explore inspection and documentation →

KNOWLEDGE & RESOURCES

Questions and product resources.

Frequently asked questions

Does self-tapping mean no pilot hole is needed?

A suitable pilot hole is still required. Whether pre-tapping is needed depends on the material and installation process.

Can I select a 302H using another brand's model designation?

No. Suffixes and dimensions may follow each manufacturer's own naming system. Check the ZCOIL drawing.

Application directions

Thread reinforcement in suitable materialsSolid connections with sufficient spaceParts requiring assessment of self-tapping processes

Tooling and technical questions

Provide the product drawing, substrate, hole and assembly method. Wire-insert STI, length and locking rules do not automatically apply to solid inserts.

Discuss specifications and tooling.

Contact ZCOIL by phone or email with a drawing, designation or current issue.

Contact ZCOIL ↗